Sygnus X-1

The Sygnus X-1 reduces common mode and differential mode noise, making your audio system sound significantly better. Four key components in this audio power conditioner are responsible for improving sound quality:

Galvanic isolation
The system provides galvanically isolated power outputs, which means that the 230VAC outputs are isolated from the mains. This eliminates most of the common mode noise, which is the key for creating a stable ground as a reference in your audio system.
Balanced power outputs
The outputs contains two phases of 115VAC each, with respect to ground. This ensures that the differential mode noise is balanced with respect to ground. As a result, the differential mode noise will drain less current to the ground, which results is a cleaner groundfor your audio system.
Dedicated audio ground

For further improvement, the Sygnus X-1 offers the option to disconnect from the protective earth provided by the wall outlet. This way a dedicated audio groundcan be created to optimize the stability of the ground and power of the audio system.

Input and output filters

Filters are applied to both the input and output to fine-tune the system to your liking. These filters can be set when the system is turned on, providing the unique ability to instantly hear the effect of a change in filter settings.

Safety features

Earth Leakage Circuit Breaker
Due to the galvanic isolation, the Earth Leakage Circuit Breaker in the fuse box does not respond to the Earthfault current at the output. The built-in audiophile Earth Leakage Circuit Breaker prevents possible danger from leakage currents. The operation can be checked with a test button.
System Earth protection
When using a separate System Earth, a safety system compares the potential of the System Earth with the Protective Earth. If the voltage difference becomes too high, the system switches off to prevent damage or unsafe situations.
Overload protection
Overloading can lead to overheating of the system. While short-term overloading usually does not cause problems, the overload protection ensures that the device remains protected from damage.
Short-circuit protection
The system is equipped with a fuse that acts as short-circuit protection.

The Sygnus X-1 is a 1000VA power processor and distribution unit designed to provide a clean power supply for audio equipment. It reduces noise from both the mains and the individual audio components, which can improve the sound quality of your audio system.

It reduces common mode and differential mode noise. It achieves this through several features, including galvanic isolation, which electrically isolates the outputs from the mains , and input/output filters that suppress mains pollution.

The Sygnus X-1 has 8 power outlets for your audio components.

What is a “Dedicated System Earth”? A Dedicated System Earth is an earth connection for your audio system that is separate from the Protective Earth provided by the wall outlet. This can optimize the stability of the earth and power, further improving sound quality.

The system has several built-in protections, including a thermal switch for overload protection , a cartridge fuse for short-circuit protection , an audiophile Earth Leakage Circuit Breaker (ELCB) , and a System Earth Voltage Circuit Breaker.

  1. Switch off the Sygnus X-1 using the power switch on the back.

  2. Remove all audio device plugs.

  3. Switch the unit back on. The Earth Leakage indicator should light up green.

  4. Insert the supplied Test Plug into one of the power outputs. The ELCB should activate, causing the device to switch off and the Earth Leakage indicator to turn red. It is recommended to perform this test monthly.

The input and output filters can be adjusted while the system and connected audio equipment are on, allowing you to hear the effect of the changes immediately. The input filter has two switches (C1 and C2 input) with four possible settings. The output filter has three switches (C1, C2, and C3 output) with eight possible settings. You should set the volume low when changing filter settings to avoid a “pop” sound that could damage your speakers.

  1. Place the unit on a firm, stable surface, away from sensitive audio sources to minimize electromagnetic interference. It weighs over 40 kg, so it is recommended to have two people move it.

  2. Ensure all switches are in the off position, then connect the power cord.

  3. Connect your audio devices to the outlets, making sure the cables are not twisted together and are run separately.

  4. Set the filters to a medium setting (C1 input on, C3 output on, others off) and power on the system to check if it’s working.

This could be due to a blown fuse at the power inlet, a defective power cord, or an overload that caused the system to shut down. Check the fuse, try a different cord or outlet, and if an overload occurred, remove the cause and wait for the unit to cool down.

This indicates that the voltage between the System Earth and the Protective Earth has exceeded the safety threshold of 20 VRMS. This can happen if the “Sys. Earth” switch is on but no earth source is connected to the Central Earth, or if the connection is poor. You can reset the system by turning the power switch off and on again.

How to connect the Sygnus X-1

There are three common ways to connect the Sygnus X-2 to your audio system. The images below show these setups.

“An audio system is as good as its power supply”


This is because the power supply is in the loop of the electrical parts that generate and amplify the audio. But you can also state that an audio system is as good as the quality of the mains power, because the electricity grid is part of the power supply.
 
Since pollution on the mains is increasing due to the proliferation of (bad) electrical appliances, such as LED lighting and smartphone chargers, it makes sense to see what can be done locally to improve the power quality for your audio system.
 
Installing a good line conditioner and the use of a dedicated System Ground will almost always breathe new life into an audio system.

Specifications

Electrical characteristics​

Parameter Minimum Typical Maximum Unit
Max. constant output power 1000 VA
Efficiency >96 %
Input voltage 207 230 253 VAC
No load voltage output 230 VAC
Full load voltage output 224 VAC
Input frequency 47 50/60 63 Hz
Inrush Current <20 A

Features

Parameter Description
Conversion Galvanically isolated balanced output
System Earth Selectable disconnection of the protective earth
Input filter Hot configurable LC filter – 4 settings
Output filter Hot configurable LC Filter – 8 settings
Electromagnetic shielding Integrated shield & thick steel enclosure

Connections

Parameter Description
Power input connector IEC320-C13
Output connectors 8x schuko (type E or type F)
Earth connectors 4x gold plated banana 4mm

Protective measures

Parameter Description / typical Unit
Input fuse type 20x5mm cartridge fuse
Input fuse specification 6,3AT / 500V / Breaking Capacity 1500A
Overload protection Thermal Switch
Earth Leakage Circuit Braker 10 mA rms
Audio Earth voltage cut-off 20 Vtop
MODELPrice including 21 % VATPrice excluding VAT
Sygnus X-1€ 5.995,00€ 4.736,05
Sygnus X-2€ 7.995,00€ 6.316,05

QUOTAION